Features
  • Low temperature drift
  • 6-digit LED digital display
  • Digital/physical calibration optional
  • Small size, DIN35 rail installation
  • Optional button or host computer driver software operation
  • Addresses can be set to achieve up to 99 networking
  • Protocol: RS232, RS485, CAN, CC-Link, PROFINET, Ethernet/IP, Modbus-TCP, Profibus-DP
  • Analog output: 0 ~ 20mA4, ~ 20mA1, ~ 5V, 0 ~ 10V(Option)
  • 4-channel optocoupler isolation switch input, each channel can be used for tare, clearing, net weight and gross weight conversion
  • Relay isolated output (0.4 channel optional), each channel can be configured for high and high
  • Limit, high limit, low limit, low and low limit, fast add, slow add, discharge, mounting option
Specifications
  • Power: DC 24V (18V-30V)
  • Operating Temp: From -5°C to 45°C (23°F to 117°F)
  • Display Range: 100 - 900,000
  • Output Sensitivity: 0.5µV/d ~ 200µ/d
  • Span Stability: Reading ±8ppm/k
  • Nonlinear error: ≤0.005% of full scale
  • Sampling Rate: Max 100 times/sec
  • Load Cell Excitation: DC0V±5%, Max.15mA
  • Consumption power: Max. 10W
  • Humility: ≤90% relative humidity (no condensation)
  • Division Display Range: 1, 2, 5, 10, 20 or 50
  • Zero Voltage Range: 0.08mV ~ 15.0mV
  • Temperature Coefficient: nt≤ (reading 0.0008%+0.3)/°C
  • Sampling Method: Delta-sigma
  • Internal Resolution: 16,000,000
  • Maximum Display Divisions: 200,000d
Features
  • Low temperature drift
  • 6-digit LED digital display
  • Digital/physical calibration optional
  • Small size, DIN35 rail installation
  • Optional button or host computer driver software operation
  • Addresses can be set to achieve up to 99 networking
  • Protocol: RS232, RS485, CAN, CC-Link, PROFINET, Ethernet/IP, Modbus-TCP, Profibus-DP
  • Analog output: 0 ~ 20mA4, ~ 20mA1, ~ 5V, 0 ~ 10V(Option)
  • 4-channel optocoupler isolation switch input, each channel can be used for tare, clearing, net weight and gross weight conversion
  • Relay isolated output (0.4 channel optional), each channel can be configured for high and high
  • Limit, high limit, low limit, low and low limit, fast add, slow add, discharge, mounting option
Specifications
  • Power: DC 24V (18V-30V)
  • Operating Temp: From -5°C to 45°C (23°F to 117°F)
  • Display Range: 100 - 900,000
  • Output Sensitivity: 0.5µV/d ~ 200µ/d
  • Span Stability: Reading ±8ppm/k
  • Nonlinear error: ≤0.005% of full scale
  • Sampling Rate: Max 100 times/sec
  • Load Cell Excitation: DC0V±5%, Max.15mA
  • Consumption power: Max. 10W
  • Humility: ≤90% relative humidity (no condensation)
  • Division Display Range: 1, 2, 5, 10, 20 or 50
  • Zero Voltage Range: 0.08mV ~ 15.0mV
  • Temperature Coefficient: nt≤ (reading 0.0008%+0.3)/°C
  • Sampling Method: Delta-sigma
  • Internal Resolution: 16,000,000
  • Maximum Display Divisions: 200,000d