LONGTEC Dynamic Weighing Transmitter - TR700LF
Review: 5 - "A masterpiece of literature" by , written on May 4, 2006
I really enjoyed this book. It captures the essential challenge people face as they try make sense of their lives and grow to adulthood.

LONGTEC Dynamic Weighing Transmitter - TR700LF

Available: In Stock
  • Order within
Features
  • Fits all resistive strain gauge load cells
  • High-precision m/V meter function; directly display the weighing m/V signal value
  • Control object non linear auto-tuning function
  • The advanced model control calculation can accurately predict the effect of each control value and adjust in advance
  • The incremental control strategy is adopted, and the control output does not fluctuate when the system switches between manual/automatic control
  • It can be used as a component module of PWC network to form a powerful distributed weightless scale and belt scale
  • Dosing system, also available independently of PWC with volume metering mode function
  • Clear OLED display, English & Chinese menus, easy to use 4 isolated switch input, 4 photo-relay outputs
  • 1 channel 4-20mA signal input, 1 channel 4-20mA output, 2 channel 4-20mA output (optional)
  • RS-485 interface (support modus), CAN interface (support CAN-open, Ethernet, Modus-TCP/IP)
  • All port functions can be customized
  • Two-stage PID Data Processing fast control speed and high precision
  • Application Field - Suitable for dynamic weighing systems such as  loss-in-weight scales, spiral scales, belt scales, etc. (Control by PLC or PC)
Specifications
  • Power: DC 24V (18V-30V)
  • Operating Temp: From -5°C to 45°C (23°F to 117°F)
  • Output Sensitivity: 0.5/D ~ 200 u/D
  • Zero Voltage Range: 0.05mV ~ 15.0mV
  • Span Stability: Reading ±8ppm/kk
  • Nonlinear error: ≤ Full scale 0.005%
  • Sampling Rate: Max 100 times/sec
  • Maximum Display Divisions: 50,000d
  • Internal Resolution: 16,000,000
  • Power Consumption: Max. 10W
  • Humidity: ≤90% relative humidity (No condensation)
  • Input Resistance: When DC500V, the impedance between each terminal should not be less
  • Signal Input Range: 0mV - +31mV
  • Temperature Coefficient: ≤ reading 0.0008%+0.3
  • Sampling Method: Delta-sigma
  • Load Cell Input Volt: DC10V±5%, A max. current of 230mV can be provided, that is, 8 sensors of 350ohms
  • TR700-BC/BS Pulse Signal Input Range: 5Hz ~ 4KHz
Features
  • Fits all resistive strain gauge load cells
  • High-precision m/V meter function; directly display the weighing m/V signal value
  • Control object non linear auto-tuning function
  • The advanced model control calculation can accurately predict the effect of each control value and adjust in advance
  • The incremental control strategy is adopted, and the control output does not fluctuate when the system switches between manual/automatic control
  • It can be used as a component module of PWC network to form a powerful distributed weightless scale and belt scale
  • Dosing system, also available independently of PWC with volume metering mode function
  • Clear OLED display, English & Chinese menus, easy to use 4 isolated switch input, 4 photo-relay outputs
  • 1 channel 4-20mA signal input, 1 channel 4-20mA output, 2 channel 4-20mA output (optional)
  • RS-485 interface (support modus), CAN interface (support CAN-open, Ethernet, Modus-TCP/IP)
  • All port functions can be customized
  • Two-stage PID Data Processing fast control speed and high precision
  • Application Field - Suitable for dynamic weighing systems such as  loss-in-weight scales, spiral scales, belt scales, etc. (Control by PLC or PC)
Specifications
  • Power: DC 24V (18V-30V)
  • Operating Temp: From -5°C to 45°C (23°F to 117°F)
  • Output Sensitivity: 0.5/D ~ 200 u/D
  • Zero Voltage Range: 0.05mV ~ 15.0mV
  • Span Stability: Reading ±8ppm/kk
  • Nonlinear error: ≤ Full scale 0.005%
  • Sampling Rate: Max 100 times/sec
  • Maximum Display Divisions: 50,000d
  • Internal Resolution: 16,000,000
  • Power Consumption: Max. 10W
  • Humidity: ≤90% relative humidity (No condensation)
  • Input Resistance: When DC500V, the impedance between each terminal should not be less
  • Signal Input Range: 0mV - +31mV
  • Temperature Coefficient: ≤ reading 0.0008%+0.3
  • Sampling Method: Delta-sigma
  • Load Cell Input Volt: DC10V±5%, A max. current of 230mV can be provided, that is, 8 sensors of 350ohms
  • TR700-BC/BS Pulse Signal Input Range: 5Hz ~ 4KHz